6HD7
Medium-Mu Triode - Sharp-Cutoff Pentode

EIA Base & Outline

EIA Base: 9QAEIA Bulb: 6-2

Substitute Data

Preferred Substitutes ......................... 6GX7 6HJ7
Substitutes ................................... 6HD7 6HB7
Source ........................................ GE - 1973

Mechanical Data

Source ........................................ GE - 1973
Bulb .......................................... T-6 1/2
EIA Outline ................................... 6-2
EIA Base ...................................... 9QA

Electrical Data

Source ........................................ GE - 1973
Heater Voltage ................................ 6.3 V
Heater Current ................................ 0.45 A

Maximum Ratings (Design Center Values)

Pentode
Source ........................................ GE - 1973
Plate Voltage ................................. 275 V
Grid No. 2 Voltage ............................ 3.5 V
Plate Dissipation ............................. 2.2 W
Grid No. 2 Dissipation ........................ 275 W

Triode
Source ........................................ GE - 1973
Plate Voltage ................................. 275 V
Plate Dissipation ............................. 1.5 W

Characteristics and Typical Operation

Triode Class A Amplifier
Source ........................................ GE - 1973
Plate Voltage ................................. 125 V
Grid No. 1 Voltage ............................ -1 V
Transconductance .............................. 9500 µMho
Plate Current ................................. 19 mA

Pentode Class A Amplifier
Source ........................................ GE - 1973
Plate Voltage ................................. 125 V
Grid No. 2 Voltage ............................ 125 V
Grid No. 1 Voltage ............................ -1 V
Transconductance .............................. 7000 µMho
Plate Current ................................. 12 mA
Grid No. 2 Current ............................ 3.5 mA

A horizontal ribbon.

If you are uncertain about the EIA designator for a particular tube please use the "Index" button to list all the tubes in the database. You can click on the designator for the closest tube.

Please enter the tube number:

This database contains data on thousands of tubes. Every effort has been made to insure the accuracy of this reference, however, I assume no liability for the results of using information contained herein.

Other Tube Search Engines:
Frank's Electron Tube Pages

Complete Tube Manuals:
Tube Manual Index from NJ7P

A horizontal ribbon.

(c) 1994-2021 by William A. Beech, NJ7P

Thu, 29 Sep 2022 00:42:29 -0700