NJ7P SQL Tube Database Query

A horizontal ribbon.

Note: Please do not link down into my pages. I change this directory structure often and your links will not work correctly.

A horizontal ribbon.

3AP1A
Electrostatic CRT

EIA Base & Outline

EIA Base: 7CE
Source ........................................ Sylvania - 1959

Mechanical Data

Source ........................................ Sylvania - 1959
Bulb .......................................... J24C
Base Type ..................................... Medium 7-Pin (A7-13)
Maximum Overall Height ........................ 11-1/2 In.
Maximum Diameter .............................. 3 In.
EIA Base ...................................... 7CE
Minimum Useful Screen Diameter ................ 2-3/4 In.

General Data

Source ........................................ Sylvania - 1959
Focusing Method ............................... Sylvania - 1959
Deflecting Method ............................. Electrostatic
Deflecting Angle (approx) ..................... Electrostatic Deg.
Fluorescence ............................... P1
Phosphorescence ............................ Green
Faceplate ..................................... Medium

Electrical Data

Source ........................................ Sylvania - 1959
Heater Voltage ................................ 2.5 V
Heater Current ................................ 2.1 A

Direct Interelectrode Capacitances (approx)

Oscilloscope
Source ........................................ Sylvania - 1959
Grid to All Other ............................. 9 pf
D1 to All Others .............................. 8.5 pf
D3 to All Others .............................. 6.5 pf

Maximum Ratings (Design Center Values)

Oscilloscope
Source ........................................ Sylvania - 1959
Anode No. 2 Voltage ........................... 1650 V
Anode No. 1 Voltage ........................... 1100 V
Grid Voltage
Negative Bias Value ........................ 125 V
Positive Bias Voltage ...................... 0 V
Peak Voltage Between Anode No. 2 and
Any Deflection Plate ....................... 550 V
Grid Circuit Resistance ....................... 1.5M Ω
Deflection Circuit Resistance ................. 5.0M Ω

Characteristics and Typical Operation

Oscilloscope
Source ........................................ Sylvania - 1959
Anode No. 2 Voltage ........................... 1500 V
Anode No. 1 Voltage ........................... 240 to 560 V
Grid No. 1 Voltage Required for Cutoff ........ -25 to -75 V
Deflection Factor
Deflecting Plates No. 1 & 2 ................... 90 to 137 V/In
Deflecting Plates No. 3 & 4 ................... 88 to 130 V/In

Oscilloscope
Source ........................................ Sylvania - 1959
Anode No. 2 Voltage ........................... 1000 V
Anode No. 1 Voltage ........................... 285 V
Grid No. 1 Voltage Required for Cutoff ........ -33 V
Deflection Factor
Deflecting Plates No. 1 & 2 ................... 77 V/In
Deflecting Plates No. 3 & 4 ................... 72.5 V/In

Oscilloscope
Source ........................................ Sylvania - 1959
Anode No. 2 Voltage ........................... 600 V
Anode No. 1 Voltage ........................... 170 V
Grid No. 1 Voltage Required for Cutoff ........ -20 V
Deflection Factor
Deflecting Plates No. 1 & 2 ................... 46 V/In
Deflecting Plates No. 3 & 4 ................... 44 V/In

Notes

Source ........................................ Sylvania - 1959
1. With D2 positive with respect to D1, the spot is deflected toward pin 1. With D4 positive with respect to D3, the spot is deflected toward pin 6.

2. Brillance and definition decrease with decreasing Anode No. 2 Voltage. In general, Anode No. 2 voltage should not be less than 1000 volts.

3. Visual extinction of undeflected spot.

4. The plane through the tube axis and Pin 6 may vary from the trace produced by Deflecting Plates 3-4 by an angular tolerance measured about the tube axis; of 10 degrees.

5. Angle between D1-D2 trace and D3-D4 trace is 90 degrees +/- 3 degrees.

6. Deflecting Plates 1-2 are nearer the screen.

7. Deflecting Plates 3-4 are nearer the base.

A horizontal ribbon.

If you are uncertain about the EIA designator for a particular tube please use the "Index" button to list all the tubes in the database. You can click on the designator for the closest tube.

Please enter the tube number:

This database contains data on thousands of tubes. Every effort has been made to insure the accuracy of this reference, however, I assume no liability for the results of using information contained herein.

Other Tube Search Engines:
Frank's Electron Tube Pages

Complete Tube Manuals:
Tube Manual Index from NJ7P

A horizontal ribbon.

(c) 1994-2021 by William A. Beech, NJ7P

Tue, 21 Mar 2023 04:43:13 -0700